Tanks for industry


Group of tanks made of nr. 3 vertical tanks with, 1 flat base capacity 25 cm and 2 static clarifier capacity 3 cm


Group of tanks made of nr. 8 vertical tanks with flat base capacity 100 cm


Above ground horizontal tanks Capacity 40 cm


Group of tanks made of nr. 17 vertical tanks with flat base capacity 35, 60 and 100 cm


Above ground horizontal tank Capacity 30 cm


Group of tanks made of nr. 3 vertical tanks with flat base capacity 90 cm


POTABILISATION PLANT STANDIANA (Ravenna)
Group of tanks made of nr. 19 vertical tanks with flat base of various capacities (65-40-30-15-14-3-2-1,5 cm)


GRP filters for water clarifiers
Battery no. 5 filters Ø2000 mm H2500 mm, working pressure 2,5 bar, test pressure 3.75 bar.


Static clarifier
with disc pack. Capacity 10 cm


Vertical tank
with conical bottom
with hydrocarbon separation system
Capacity 15 cm


Above ground horizontal tanks
Capacity 80 cm


Underground horizontal tank
Capacity 64 cm


Vertical tanks
with flat base with containment tank
Capacity 30 cm


Vertical tanks
with conical bottom
Foamed polyurethan insulated
Capacity 50 cm


Static clarifier


Vertical tank with flat base
Capacity 65 cm


Vertical tank with flat base
Foamed polyurethan insulated
Capacity 10 cm


Group of tanks
made of:
nr. 5 vertical tanks with flat base capacity 50 cm
nr. 4 vertical tanks with conic bottom capacity 100 cm


Vertical tanks with round base
Capacity 9,5 cm


Vertical tanks with round base
for waste leachate
Capacity 10 cm


Stripping towers
Height 11 m


Vertical tank with round base
quarzite filter pressure 5 bar
Capacity 15 cm


Static clarifiers
Capacity 20 cm


Above ground horizontal tank
Capacity 25 cm


CENTRO OLIMPICO TORINO 2006
Underground horizontal tanks for fire extinguishing unit
Capacity 50 cm


Underground horizontal tank
for fire extinguishing unit
Capacity 24 cm
Wastewater treatment units


Biological plant
for treatment of discharges coming from company producer of balsamic vinegar
Layout: 1 horizontal tank and 5 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 3 "Limit values for wastewater discharged into water bodies" provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 5 I.E.
Hydraulic flow: 1,000 litres/day
Layout: 1 vat


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 800 I.E.
Hydraulic flow: 160,000 litres/day
Layout: 22vats on 3 lines


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil" provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 150 I.E.
Hydraulic flow: 30,000 litres/day
Layout: 12vats on 2 lines


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 70 I.E.
Hydraulic flow: 14,000 litres/day
Layout:4 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 160 I.E.
Hydraulic flow: 32,000 litres/day
Layout: 7 vats on 2 lines


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 150 I.E.
Hydraulic flow: 30,000 litres/day
Layout: 12 vats on 2 lines


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 200 I.E.
Hydraulic flow: 40,000 litres/day
Layout: 11 vats on 2 lines


Universal constant flow system
Conforming to the parameters of Table 4 "Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 70 I.E.
Hydraulic flow: 14,000 litres/day
Layout: 3 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 ”Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 230 I.E.
Hydraulic flow: 46,000 litres/day
Layout: 6 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 350 I.E.
Hydraulic flow: 70,000 litres/day
Layout: 10 vats on 2 parallel lines


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 350 I.E.
Hydraulic flow: 70,000 litres/day
Layout: 10 vats on 2 parallel lines


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 500 I.E.
Hydraulic flow: 100,000 litres/day
Layout: 2 horizontal tanks and 2 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 350 I.E.
Hydraulic flow: 70,000 litres/day
Layout: 12 vats on 2 lines


Universal constant flow system
Conforming to the parameters of Table 3 Limit values for wastewater discharged into water bodies provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 40 I.E.
Hydraulic flow: 8,000 litres/day
Layout: 2 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 35 I.E.
Hydraulic flow: 7,000 litres/day
Layout: 1 vat


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 70 I.E.
Hydraulic flow: 14,000 litres/day
Layout: 3 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil” provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 500 I.E.
Hydraulic flow: 100,000 litres/day
Layout: 15 vats on 3 parallel lines


Universal constant flow system
Conforming to the parameters of Table 3 Limit values for wastewater discharged into water bodies provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 200 I.E.
Hydraulic flow: 40,000 litres/day
Layout: 5 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 3 Limit values for wastewater discharged into water bodies provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 40 I.E.
Hydraulic flow: 8,000 litres/day
Layout: 2 vats on 1 line


Universal constant flow system
Conforming to the parameters of Table 3 Limit values for wastewater discharged into water bodies provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 360 I.E.
Hydraulic flow: 72,000 litres/day
Layout: 10 vats on 2 lines and final chlorination


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 500 I.E.
Hydraulic flow: 100,000 litres/day
Layout: 15 vats on 3 parallel lines


Universal constant flow system
Conforming to the parameters of Table 4 Limit values for wastewater discharged into soil provided for in Enclosure 5, Section 3 of Legislative Decree 152/2006.
Type of sewage: civil waste
Capacity: 140 I.E.
Hydraulic flow: 28,000 litres/day
Layout: 5 vats on 1 line